Application
FLEX-TVVRPS represents a premium-grade cable distinguished by its exceptional flexibility, meticulously engineered for unceasing motion. Its construction boasts the advantage of a reduced bending radius, making it the ideal choice across an array of industries. Applications spanning material handling, automated technologies, woodworking, packaging machinery, industrial robotics, automotive production, and logistics conveyance systems all stand to benefit immensely from its superior attributes.
Model
FLEX-TVVRPS
Type
Drag Chain Shielded Data Cable
Brand
Red Banner Electrician
Approvals
CE, RoHS
Bend-resistant
Designed for over 10 million bend cycles
Shielding
Overall Shield (S/UTP)
Waterproof
Yes
Oil-proof
Yes
Halogen-free
No
Flame-retardant
Acc. to IEC 60332-1-2, UL VW-1, CSA FT1
Cold-resistant
Yes
Wear-resistant
Yes
Conductor
Stranded conductor in extra fine bare copper and aramid fiber (acc. to DIN EN 60228)
Conductor insulation
Special Thermoplastic elastomer (TPE) mixture for drag chains
Conductor construction
Every two cores are twisted in pairs with a short pitch lengths
Filling
Cotton yarns
Overall banding
Non-woven tape
Elements shield
No
Overall shield
Tinned-copper braid shielding, coverage approx. 90 % optical
Outer jacket
Flexible wear-resisting sheath Polyvinyl chloride (PVC) mixture for drag chains
Rated Voltage U0/U
300/300V
Test Voltage
2000V
Rated Temperature
Fixed Installation
-30℃ to +90℃
Flexible Installation
-5℃ to +90℃
Minimum Bending Radius
Fixed Installation
5 x Overall Diameter
Flexible Installation
7.5 x Overall Diameter
Conductor Cross-Section
mm²(AWG)
Conductor Resistance
Ω/km (20℃)
Insulation Resistance
Ω-km (20℃)
Voltage Withstand
V · 1 minute
0.2 (25 gauge)
Below 102
Above 100
AC 2000
0.3 (25 gauge)
Below 68
Above 100
AC 2000
0.5 (25 gauge)
Below 45
Above 100
AC 2000
Drag Chain Cable Test
Performance
Over 10,000,000 cycles
Test Conditions
Bending radius: Approximately 6 times the sample's diameter
Sliding speed: 70 cycles/minute
Movement distance: 500mm
Count by: 1 round trip counts as 1 cycle
90° Bending Test
Performance
Over 1,000,000 cycles
Test Conditions
Bending radius: Approximately 8 times the sample's diameter
Bending angle: ±90°
Bending speed: 40 cycles/minute
Load: 4.0N
Count by: 1 round trip counts as 1 cycle
180° Vorsion Test
Performance
Over 1,000,000 cycles
Test Conditions
Torsion angle: ±180°
Torsion speed: 12 cycles/minute
Distance: 200mm
Count by: 1 round trip counts as 1 cycle
2 Core
Brown, Blue
3 Core
Brown, Blue, Yellow/Green
4 Core
Brown, Black, Grey, Yellow/Green
5 Core
Brown, Blue, Black, Grey, Yellow/Green
6 Core
Brown, Blue, Black, Grey, Red, Yellow/Green
7 Core
Brown, Blue, Black, Grey, Orange, Red, Yellow/Green
8 Core
Number Coded